Colfax Pumps and Systems in Power Generation Applications

Large frame-sized turbines found in utility scale steam‚ combustion and combined cycle power plants use high-pressure hydraulic oil pumps to lift the turbine shaft from its sleeve bearings before the turbine is started. Hot turbines that are being shut down are put on “turning gear” drive. This allows the turbine to rotate very slowly while it cools so its shaft does not sag due to its weight. A hydraulic oil motor drives a gear which maintains this slow rotation of the turbine shaft.

When evaluating a pump for this application‚ ensure that the pump and inlet piping are properly sized to handle cold start conditions because lower temperature affects the viscosity of the lubrication oil and Net Positive Inlet Pressure Available (NPIPA). The lift capability of a pump decreases with temperature.

Suitable pumps here are three screw and crescent internal gear pumps.

Flow Rates up toPressures to up toMax Fluid TemperatureColfax Brand‚ Series & Pump Type
13 m^3/h
55 GPM
210 bar
3‚046 psi
80C
176F
Allweiler SD
Three Screw
28 m^3/h
125 GPM
345 bar
5‚000 psi
82C
180F
IMO CIG
Crescent Internal Gear
91 m^3/h
400 GPM
151 bar
2‚200 psi
120C
250F
IMO 12D
Three Screw

Contact Colfax to learn more about our pump and engineered system capabilities:  AmericasEMEAAsia